3516C Diesel Generator Sets
3516C Package Genset, Rear Right
3516C Package Genset, Rear Left
3516C Package Genset, Front Left
Diesel generator sets

3516C (60 Hz)

Producing reliable power from 1825 to 2500 ekW at 60 Hz, our 3516C diesel generator sets are made to meet your mission critical, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. The 3516C generator sets are U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards), Low Fuel Consumption certified.

  • Emissions/Fuel StrategyU.S. EPA Cert., Tier 2
  • Voltage380 to 13800 Volts
  • Frequency60 Hz
  • Duty CycleStandby, Mission Critical, Prime, Continuous
  • Maximum Rating2500 ekW
  • Minimum Rating1650 ekW
Have questions about this product?
Request a Quote
Generator Set Specifications
Standby Rating 2500/2250/2000 ekW
Prime Power Rating 2250/2045/1825 ekW
Emissions/Fuel Strategy U.S. EPA Cert., Tier 2
Voltage 380 to 13800 Volts
Frequency 60 Hz
Speed 1800 rpm
Duty Cycle Standby, Mission Critical, Prime, Continuous
Maximum Rating 2500 ekW
Minimum Rating 1650 ekW
Engine Specifications
Engine Model 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel
Bore 6.69 in
Stroke 7.48 in
Stroke - HD 8.46 in
Displacement 4764.73 in
Compression Ratio 14.7:1
Aspiration TA
Fuel System Electronic unit injection
Governor Type Adem™3
Generator Set Dimensions
Length - Minimum 266.2 in
Length - Maximum 276.3 in
Width - Minimum 92.1 in
Width - Maximum 92.1 in
Height - Minimum 118 in
Height - Maximum 118 in
Dry Weight - Genset (minimum) 35880 lb
Dry Weight - Genset (maximum) 38780 lb

Air Inlet System

  • Air cleaner; single element canister type

Cooling

  • Package mounted radiator

Exhaust

  • Exhaust flange outlet

Control Panels

  • Communications:
  • Reverse reactive power (kVAr) (32RV)
  • Customer data link (Modbus RTU)
  • Generator mounted - rear facing
  • 1 Programmable digital outputs
  • Auto/start/stop control -
  • Serial annunciator module data link
  • Engine cool-down timer
  • 24 Volt DC operation
  • Controls:
  • Generator set packages include Caterpillar's voltage regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter. Limiter and exciter diode monitor
  • Alarm acknowledge
  • Cat connect
  • Engine cycle crank
  • Text alarm/event descriptions
  • Overcurrent (50 / 51)
  • Accessory module data link
  • Cat ECS 100
  • 1 Programmable relay outputs (Form C)
  • Emergency stop pushbutton
  • Speed adjust
  • 4 Programmable relay outputs (Form A)
  • Number of I/O varies on options selected
  • 6 Customer programmable digital inputs
  • Environmental sealed front face
  • Load histogram feature
  • Lamp test
  • PLC functionality
  • Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
  • Digital indication for:
  • Operating hours
  • RPM
  • DC volts
  • Frequency (Hz)
  • Coolant temperature
  • Volts (L-L & L-N)
  • Oil pressure (psi, kPa or bar)
  • Amps (per phase & average)
  • kVAr (per phase, average & percent)
  • kVA (per phase, average & percent)
  • kW (per phase, average & percent)
  • Power factor (per phase & average)
  • kW-hr (total)
  • kVAr-hr (total)
  • High coolant temperature
  • Overspeed
  • Failure to start (overcrank)
  • Warning/shutdown with common LED indication of shutdowns for:
  • Emergency stop
  • Low oil pressure
  • Low coolant level
  • Low coolant temperature
  • Programmable protective relaying functions:
  • Over/under frequency (81 o/u)
  • Generator phase sequence
  • Over/under voltage (27 / 59)
  • Reverse power (kW) (32)

Fuel

  • Primary fuel filter with integral water separator

Generator

  • Matched to the performance and output characteristics of Cat engines
  • IP23 Protection

Power Termination

  • Busbar

Control Panel

  • Cat ECS Genset controller

Cooling System

  • Certified standard PGS provided

Exhaust System

  • Flanged faced outlet(s)
  • Dry exhaust manifold

Fuel System

  • Flexible fuel lines - shipped loose
  • Fuel cooler; not included with packages without radiator
  • Secondary fuel filters
  • Fuel priming pump

General

  • Caterpillar yellow with high gloss black rails and radiator
  • Right hand servicing
  • Flywheel and flywheel housing - SAE No. 00
  • Paint - Caterpillar yellow except rails and radiators gloss black
  • SAE standard rotation

Generator and Attachments

  • Busbar connections, top center mounted, top cable entry
  • Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • Low voltage:
  • NEMA standard hole pattern
  • Medium voltage:
  • Anti-condensation space heater
  • 6 Lead
  • Random wound
  • Form wound
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • Permanent magnet excitation (PMG)
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
  • Internal excitation (IE)
  • 3 Phase brushless, Salient pole
  • High voltage:
  • Winding temperature detectors
  • Busbar connections, right side extension box, bottom cable entry

Governing System

  • ADEM A3

Literature

  • Parts book

Lubrication System

  • Lubricating oil
  • Fumes disposal
  • Integral lube oil cool
  • Oil drain lines and valve
  • Oil filter, filler and dipstick
  • Gear type lube oil pump

Mounting System

  • Anti-vibration mounts (shipped loose)
  • Rubber anti-vibration mounts - shipped loose
  • Rails - engine/generator/radiator mounting

Starting System

  • Battery disconnect switch
  • 45 Amp Charging alternator
  • 24 Volt electric starting motor
  • Battery and battery rack w/cables
  • Electric Power Ratings Guide
    application/pdf
    Download ↓
  • 3516C, 60 Hz, 1650-2000 ekW, U.S. EPA Stationary Emergency (Tier 2) Spec Sheet
    text/html
    Download ↓
  • 3516C 60Hz, 2045-2250 ekW, U.S. EPA Stationary Emergency (Tier 2) Spec Sheet
    text/html
    Download ↓
  • 3516C 60 Hz, 2050-2500 ekW, U.S. EPA Stationary Emergency (Tier 2) Spec Sheet
    text/html
    Download ↓
  • 3516C, 60 Hz, Prime-DCP 1825 ekW, U.S. EPA Stationary Emergency (Tier 2) Spec Sheet
    text/html
    Download ↓
  • 3516C 60Hz, Prime-DCP 2045 ekW, U.S. EPA Stationary Emergency (Tier 2) Spec Sheet
    text/html
    Download ↓
  • 3516C 60 Hz, Prime-DCP 2250 ekW, U.S. EPA Stationary Emergency (Tier 2) Spec Sheet
    text/html
    Download ↓
  • 3516C 60Hz Enclsoure 2000 ekW
    application/pdf
    Download ↓
Need installed dimensions with enclosure and tank? See Model Configurations