3516B Diesel Generator Sets Front right
3516 DGB Generator Set Front Left
3516 DGB Generator Set Rear Left
3516 DGB Generator Set Front Right
Diesel generator sets

3516B DGB™ (50 Hz)

The 3516B DGB (Dynamic Gas Blending) generator sets are made to match your continuous and prime applications. Producing reliable power from 1750 to 2275 kVA at 50 Hz, each generator set has been designed to meet ISO 8528-5 transient response requirements and accepts 100 % rated load in one step. Our 3516B DGB generator sets have been developed for low fuel consumption.

  • Emissions/Fuel StrategyLow Fuel Consumption
  • Voltage380 to 11000 Volts
  • Frequency50 Hz
  • Duty CyclePrime, Continuous
  • Maximum Rating2275 kVA
  • Minimum Rating1750 kVA
Have questions about this product?
Request a Quote
Generator Set Specifications
Prime Power Rating 2275/2000 kVA
Continuous Rating 2000/1750 kVA
Emissions/Fuel Strategy Low Fuel Consumption
Voltage 380 to 11000 Volts
Frequency 50 Hz
Speed 1500 rpm
Duty Cycle Prime, Continuous
Maximum Rating 2275 kVA
Minimum Rating 1750 kVA
Engine Specifications
Engine Model 3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Bore 6.69 in
Stroke 7.48 in
Stroke - HD 8.46 in
Displacement 4210.64 in
Displacement - HD 4764.73 in³
Compression Ratio 14.0:1 Std 15.5:1 HD
Aspiration TA
Fuel System Electronic unit injection
Governor Type Adem™4
Generator Set Dimensions
Length - Minimum 268.3 in
Length - Maximum 276.1 in
Width - Minimum 90.1 in
Width - Maximum 90.1 in
Height - Minimum 94.1 in
Height - Maximum 94.1 in
Dry Weight - Genset (minimum) 33300 lb
Dry Weight - Genset (maximum) 36280 lb

Air Inlet System

  • Air cleaner, single element canister type

Control System

  • Low oil pressure
  • Over/under frequency (81 o/u)
  • Alarm acknowledge
  • Oil pressure (psi, kPa or bar)
  • Reverse reactive power (kVAr) (32RV)
  • 3 Analog inputs
  • Programmable protective relaying functions:
  • 4 Programmable relay outputs (Form A)
  • Overspeed
  • Reverse power (kW) (32)
  • Customer data link (Modbus RTU)
  • Text alarm/event descriptions
  • Low coolant temperature
  • Number of I/O varies on options selected
  • Emergency stop
  • Operating hours
  • Limiter and exciter diode monitor
  • Environmental sealed front face
  • kW (per phase, average & percent)
  • Digital indication for:
  • Auto/start/stop control
  • Cat connect
  • Low coolant level
  • Controls:
  • Serial annunciator module data link
  • Regulator (IVR) - IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
  • RPM
  • Volts (L-L & L-N), frequency (Hz)
  • Coolant temperature
  • 1 Programmable digital outputs
  • Speed adjust
  • Engine cycle crank
  • Over/under voltage (27/59)
  • kW-hr (total)
  • 6 Customer programmable digital inputs
  • Generator phase sequence
  • 1 Programmable relay outputs (Form C)
  • PLC functionality
  • kVAr-hr (total)
  • DC volts
  • Engine cool-down timer
  • 24 Volt DC operation
  • Generator mounted - rear facing
  • High coolant temperature
  • Amps (per phase & average)
  • Load histogram feature
  • Emergency stop pushbutton
  • Warning/shutdown with common LED indication of shutdowns for:
  • kVAr (per phase, average & percent)
  • Customizable screens
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Overcurrent (50/51)
  • Communications:
  • kVA (per phase, average & percent)
  • Power factor (per phase & average)
  • Failure to start (overcrank)
  • Accessory module data link
  • Lamp test
  • Generator set packages include Caterpillars voltage regulator

Exhaust

  • Exhaust flange outlet

Fuel

  • Primary fuel filter with integral water separator

Generator

  • IP23 Protection

Power Termination

  • Busbar

Control Panel

  • Cat ECS Genset controller

Cooling System

  • Package mounted radiator

Exhaust System

  • Dry exhaust manifold
  • Flanged faced outlet(s)

Fuel System

  • Fuel priming pump
  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
  • Secondary fuel filters

General

  • SAE standard rotation
  • Paint - Caterpillar yellow except rails and radiators gloss black
  • RH service
  • Flywheel and Flywheel housing-SAE No. 00

Generators and Attachments

  • Matched to the performance and output characteristics of Cat engines
  • Random wound
  • Busbar connections, right side extension box, bottom cable entry - 60 Hz models: NEMA standard hole pattern
  • Permanent magnet excitation (PMG)
  • LV
  • HV:
  • MV:
  • 6 Lead
  • Winding temperature detectors
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby) - 60 Hz models: NEMA standard hole pattern
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
  • 3 Phase brushless, Salient pole
  • Anti-condensation space heater
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • Form wound

Governing System

  • ADEM A3

Lube System

  • Gear type lube oil pump
  • Oil filter, filler and dipstick
  • Oil drain lines and valve
  • Integral lube Oil cooler
  • Lubricating oil
  • Fumes disposal

Mounting System

  • Rails - Engine/generator/radiator mounting
  • Rubber anti-vibration mounts - shipped loose
  • Anti-vibration mounts (shipped loose)

Starting System

  • 45 Amp Charging alternator
  • 24 Volt electric starting motor
  • Battery disconnect switch
  • Battery and battery rack w/cables
  • Electric Power Ratings Guide
    application/pdf
    Download ↓
  • 3516B DGB, 50 Hz, 2000 kVA Prime, 1750 kVA Cont., Low Fuel Consumption Spec Sheet
    application/pdf
    Download ↓
  • 3516B DGB, 50 Hz, 2275 kVA Prime, 2000 kVA Cont., Low Fuel Consumption Spec Sheet
    application/pdf
    Download ↓
Need installed dimensions with enclosure and tank? See Model Configurations