3516 (3516 MUI) Modular Rear Overhang Controls Generator Set,  Rear Right
3516 (3516 MUI) Modular Rear Overhang Controls Generator Set,  Rear Left
3516 (3516 MUI) Modular Rear Overhang Controls Generator Set,  Front Right
3516 (3516 MUI) Modular Rear Overhang Controls Generator Set,  Front Left
Diesel generator sets

3516 (60 Hz)

Producing reliable power from 1450 to 1750 ekW at 60 Hz, our 3516 diesel generator sets are made to meet your mission critical, continuous, prime and standby applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. Generator sets offer both low fuel consumption and low emission systems.

  • Emissions/Fuel StrategyLow Fuel, Low Emissions
  • Voltage380 to 13800 Volts
  • Frequency60 Hz
  • Duty CycleStandby, Mission Critical, Prime, Continuous
  • Maximum Rating1750 ekW
  • Minimum Rating1450 ekW
Have questions about this product?
Request a Quote
Generator Set Specifications
Standby Rating 1750 ekW
Prime Power Rating 1600 ekW
Emissions/Fuel Strategy Low Fuel, Low Emissions
Voltage 380 to 13800 Volts
Frequency 60 Hz
Speed 1800 rpm
Duty Cycle Standby, Mission Critical, Prime, Continuous
Maximum Rating 1750 ekW
Minimum Rating 1450 ekW
Engine Specifications
Engine Model 3516 TA, V-16, 4-Stroke Water-Cooled Diesel
Bore 6.69 in
Stroke 7.48 in
Displacement 4210.64 in³
Compression Ratio 13.0:1
Aspiration TA
Fuel System Mechanical unit injection
Governor Type Woodward
Generator Set Dimensions
Length - Minimum 245.2 in
Length - Maximum 245 in
Width - Minimum 90 in
Width - Maximum 90 in
Height - Minimum 94.9 in
Height - Maximum 94.9 in
Dry Weight - Genset (minimum) 28840 lb
Dry Weight - Genset (maximum) 28840 lb

Air Inlet System

  • Air cleaner; single element canister type

Control Panels

  • Accessory module data link
  • Low coolant level
  • Environmental sealed front face
  • EMCP 4.2B
  • 6 Customer programmable digital inputs
  • Communications:
  • Load histogram feature
  • Overspeed
  • Alarm acknowledge
  • kW-hr (total)
  • 24 Volt DC operation
  • Over/under voltage (27/59)
  • 1 programmable relay outputs (Form C)
  • kVAr-hr (total)
  • Emergency stop pushbutton
  • PLC functionality
  • Speed adjust
  • Lamp test
  • Auto/start/stop control
  • Over/under frequency (81 o/u)
  • Generator phase sequence
  • Revers Power (kW) (32)
  • Oil pressure (psi, kPa or bar
  • Coolant temperature
  • RPM
  • Overcurrent (50/51)
  • IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter. Limiter and exciter diode monitor
  • Controls:
  • Number of I/O varies on options selected
  • Power factor (per phase & average)
  • 0 True RMS AC metering, 3-phase, +/-2% accuracy
  • kVA (per phase, average & percent)
  • Serial annunciator module data link
  • Customizable screens
  • Generator mounted - rear facing
  • kW (per phase, average & percent)
  • Text alarm/event descriptions
  • DC volts
  • Low oil pressure
  • Controls: Speed adjust - Auto/start/stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test - Load histogram feature - PLC functionality - Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
  • Reverse reactive power (kVAr) (32RV
  • Frequency (Hz)
  • Low coolant temperature
  • 3 Analog inputs
  • Cat connect
  • kVAr (per phase, average & percent)
  • Warning/shutdown with common LED indication of shutdowns for:
  • Engine cycle crank
  • Failure to start (overcrank)
  • Programmable protective relaying functions:
  • Emergency stop
  • Customer data link (Modbus RTU
  • Engine cool-down timer
  • Volts (L-L & L-N)
  • Amps (per phase & average)
  • Operating hours
  • High coolant temperature
  • Digital indication for:
  • 1 programmable digital outputs
  • 4 programmable relay outputs (Form A)

Cooling System

  • Certified standard PGS provided

Exhaust System

  • Flanged faced outlet(s)
  • Dry exhaust manifold

Fuel System

  • Secondary fuel filters
  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
  • Fuel priming pump

General

  • Right hand servicing
  • Flywheel and flywheel housing - SAE No. 00
  • SAE standard rotation

Generator and Attachments

  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
  • Winding temperature detectors
  • Winding temperature detectors
  • Permanent magnet excitation (PMG)
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
  • Six lead
  • Permanent magnet excitation (PMG)
  • Internal excitation (IE)
  • 3 Phase brushless, Salient pole
  • Winding temperature detectors
  • Medium voltage:
  • Random wound
  • Anti-condensation space heater
  • Low voltage:
  • High voltage:
  • Busbar connections, top center mounted, top cable entry
  • Form wound
  • Busbar connections, right side extension box, bottom cable entry
  • Form wound
  • NEMA standard hole pattern
  • NEMA standard hole pattern

Governing System

  • ADEM A3

Literature

  • Parts book

Lubrication System

  • Fumes disposal
  • Lubricating oil
  • Gear type lube oil pump
  • Oil filter, filler and dipstick
  • Oil drain lines and valve
  • Integral lube oil cool

Mounting System

  • Rails - engine/generator/radiator mounting
  • Anti-vibration mounts (shipped loose)
  • Rubber anti-vibration mounts - shipped loose

Starting System

  • Battery and battery rack w/cables
  • 45 Amp Charging alternator
  • Battery disconnect switch
  • 24 Volt electric starting motor
  • Electric Power Ratings Guide
    application/pdf
    Download ↓
  • 3516, 60 Hz, 1750 ekW Standby/MC, 1600 ekW Prime, 1450 ekW Cont., Low Fuel Consumption Spec Sheet
    application/pdf
    Download ↓
  • 3516, 60 Hz, 1600 ekW, Prime-DCP, Low Fuel Consumption Spec Sheet
    application/pdf
    Download ↓
Need installed dimensions with enclosure and tank? See Model Configurations