Generator Set Specifications
Standby Rating605 kVA
Prime Power Rating550 kVA
Emissions/Fuel StrategyLow BSFC
Voltage380 to 415 Volts
Frequency50 Hz
Speed1500 rpm
Duty CycleStandby and Prime
Engine Specifications
Engine ModelC15 In-line 6, 4-cycle diesel
Bore5.4 in
Stroke6.8 in
Displacement928 in³
Compression Ratio16.1:1
AspirationTurbocharged Air-to-Air Aftercooled
Fuel SystemEUI
Governor TypeAdem™A4
Generator Set Dimensions
Length - Maximum131 in
Width - Maximum60.6 in
Height - Maximum86.1 in
Dry Weight - Genset (maximum)8120 lb

Engine

  • Cat® C15 Inline 6 cylinder, 4 stroke diesel

Control Panels

  • GCCP 1.1

Air Inlet

  • Air cleaner

Governor

  • Mechanical governor

Alternator

  • A Frame standard alternator

Cooling

  • Package mounted radiator

Fuel Storage

  • Single wall 8 hour fuel tank

Cooling System

  • Caterpillar extended life coolant
  • Radiator and cooling fan with guards
  • Fan drive, battery charging alternator drive

Electrical Options

  • 3 Pole Circuit breaker
  • Neutral earth link
  • 24 Volt battery with rack and cables

Fuel

  • Secondary fuel filters
  • Fuel priming pump
  • Primary fuel filter with integral water separator

Air inlet system

  • Air cleaner; light duty with disposable element

Generator

  • IP23 Protection
  • Matched to the performance and output characteristics of Cat engines
  • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time

Lube system

  • Lubricating oil
  • Oil drain line with valve

Mounting system

  • Captive linear vibration isolators
  • Lifting provision and drag points

General

  • Engine and alternator pre paint, Caterpillar yellow
  • Engine and alternator pre paint, Caterpillar yellow

Power Termination

  • Busbar

Generator and Attachments

  • Power center, IP22
  • Segregated low voltage (AC/DC) wiring panel
  • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre

Mounting

  • Rubber vibration isolators

Governing System

  • Cat electronic governor (ADEM A4).

Lube System

  • Oil cooler
  • Oil drain valves

Mounting System

  • Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines
  • DE605 GC, 50 Hz, 605 kVA, Low BSFC Spec Sheet
    application/pdf
    Download ↓
  • Electric Power Ratings Guide