C1.1 Generator Set Rear Right
C1.1 Generator Set Rear  Left
C1.1 Generator Set Front Right
C1.1 Generator Set Rear Left
Enclosure
Enclosure
Diesel generator sets

C1.1 (50 Hz)

Producing reliable power from 6.8 to 9.5 kVA at 50 Hz, our C1.1 diesel generator sets designed to ISO 8528-5 transient response requirements. All C1.1 generator sets are R96/EUIIIa equivalent emissions compliant.

Request a Quote
Have questions? Call 800.768.4200
Generator Set Specifications
Standby Rating7.5/9.5 kVA
Prime Power Rating6.8/8.5 kVA
Emissions/Fuel StrategyEU Stage IIIA
Voltage110 to 415 Volts
Frequency50 Hz
Speed1500 rpm
Duty CycleStandby, Prime
Engine Specifications
Engine ModelC1.1, In-line 4 4-cycle diesel
Bore3 in
Stroke3.2 in
Displacement69 in³
Compression Ratio23.0:1
AspirationNaturally Aspirated
Fuel SystemIndirect Injection
Governor TypeMechanical
Generator Set Dimensions
Length - Maximum55.1 in
Width - Maximum24.4 in
Height - Maximum39.2 in

Air Inlet System

  • Air cleaner; light duty with disposable element

Control Panel

  • GCCP1.3 Control panel

Cooling System

  • Caterpillar extended life coolant
  • Coolant drain line with valve
  • Fan drive, battery charging alternator drive
  • Radiator and cooling fan with guards

Exhaust System

  • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose

Fuel System

  • Base, formed steel with single wall integral 8-hour fuel tank
  • Standard open set fuel tank/base supplied

General

  • Engine and alternator pre-paint, Caterpillar yellow

Generators and Generator Attachments

  • 12 Leads
  • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • IP23 Protection
  • Segregated low voltage (AC/DC) wiring panel
  • Tower panel, IP22, bottom cable entry
  • Voltage regulator (single phase sensing)

Governing System

  • Mechanical governing system

Lube System

  • Lubricating oil
  • Oil drain line with valve

Mounting System

  • Anti-vibration mounts
  • Captive linear vibration isolators between base and engine-generator
  • Includes lifting provisions and termination points for coolant
  • Skidbase as standard

Starting / Charging System

  • 12 Volt battery with rack and cables
  • Electric Power Ratings Guide
    application/pdf
    Download ↓
  • DE7.5E3S 50 Hz 7.5 kVA, 60 Hz 8.8 kVA, M Frame, EU IIIA Compliant Emissions Spec Sheet
    application/pdf
    Download ↓
  • DE9.5E3 50 Hz 9.5 kVA, 60 Hz 11.0 kVA, M Frame, EU IIIA Emissions Compliant Spec Sheet
    application/pdf
    Download ↓
  • DE9.5E3 50 Hz 9.5 kVA, 60 Hz 11.0 kVA, M Frame, EU IIIA (EUR-1) Compliant Emissions Spec Sheet
    application/pdf
    Download ↓
  • DE7.5E3S 50 Hz 7.5 kVA, 60 Hz 8.8 kVA, LC Frame, EU IIIA Emissions Compliant Spec Sheet
    application/pdf
    Download ↓
  • DE9.5E3 50 Hz 9.5 kVA, 60 Hz 11.0 kVA, LC Frame, EU IIIA Emissions Compliant Spec Sheet
    application/pdf
    Download ↓
  • DE9.5E3 50 Hz 9.5 kVA, 60 Hz 11.0 kVA, LC Frame, EU IIIA (EUR-1) Emissions Compliant Spec Sheet
    application/pdf
    Download ↓
  • C1C2 Diesel Generator Sets, 6.8 - 22 kVA, 50/60 Hz, Spec Sheet
    application/pdf
    Download ↓
  • C1C2 Diesel Generator Sets, 6.8 - 22 kVA, 50/60 Hz, Spec Sheet
    application/pdf
    Download ↓

Need installed dimensions with enclosure and tank? See Model Configurations