The D450 GC diesel generator sets have been developed to meet your needs in standby applications. Producing reliable power of 450 ekW at 60 Hz, meeting ISO 8528-5 transient response requirements and built to accept 100 % rated load in one step. The engines are certified for U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 or Tier 3 Nonroad Equivalent Emission Standards).

Request a Quote
Have questions? Call 800.768.4200
Generator Set Specifications
Standby Rating450 ekW
Prime Power Rating410 ekW
Emissions/Fuel StrategyU.S. EPA Tier 3 Certified
Voltage480 to 600 Volts
Frequency60 Hz
Speed1800 RPM
Duty CycleStandby
Engine Specifications
Engine ModelCat® C15 In-line 6, 4-cycle diesel
Bore5.4 in
Stroke6.8 in
Displacement928 in³
Compression Ratio16.1:1
AspirationTurbocharged Air-to-Air Aftercooled
Fuel SystemMEUI
Governor TypeADEM™A4
Generator Set Dimensions
Length - Maximum189.6 in
Width - Maximum64.2 in
Height - Minimum80.1 in
Height - Maximum101.7 in
Dry Weight - Genset (minimum)8172.5 lb
Dry Weight - Genset (maximum)10238.3 lb

Air Inlet System

  • Aftercooler core
  • Turbocharger
  • Air cleaner - Non canister, disposable

Control Panel

  • GCCP 1.2

Cooling System

  • Thermostats and housing
  • Blower fan and fan drive with guards
  • Radiator, package mounted
  • Coolant drain valve
  • Jacket water pump, gear driven, centrifugal
  • Radiator sight gauge

Exhaust System

  • Exhaust manifold - dry

Fuel System

  • Fuel priming pump
  • Integral tank base, 24 hours, UL142
  • Primary fuel filter w/integral water separator and secondary filter, spin on
  • Engine fuel transfer pump
  • Fuel cooler

Generator Set

  • Complete system designed & built at ISO 9001:2000 certified facilities
  • Factory tested to design specifications at full load conditions
  • All protective devices and control functions simulated and checked

Generators and Generator Attachments

  • IP23 Protection
  • Voltage regulator (single phase sensing)
  • Easy access to AVR and terminals
  • Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
  • Terminal box, IP22 RHS facing, bottom cable entry
  • Standard winding protection for non-harsh environments with relative humidity ? 95%
  • 6 Leads
  • Insulation system, Class H

Governing System

  • Cat electronic governor (ADEM A4)

Lube System

  • Fumes disposal to front of radiator
  • Oil filter, spin on
  • Lubricating oil, CK-4 (10W-30)
  • Shallow oil pan
  • Oil cooler
  • Oil filler and dipstick
  • Oil drain with valve

Mounting System

  • Includes lifting provisions and termination points for coolant and lube oil drain lines
  • Captive linear vibration isolators between base and engine-generator

Protection

  • Safety shutoff - Low oil pressure
  • Safety shutoff - Overspeed
  • Safety shutoff - High water temperature

Starting/Charging System

  • 24-volt electric starting motor
  • 24V, 45 Amp Charging alternator

General

  • Vibration damper
  • Parts book
  • Lifting eyes
  • Electric Power Ratings Guide