Cat® Energy Control System (ECS) 400

The Cat® ECS 400 integrates advanced site controls for both traditional and hybrid microgrid systems. The Cat ECS ensures precise management of generation assets with operational reliability and optimized cost effectiveness. The system features a user-friendly and intuitive 396 mm (15.6”) color touchscreen interface.

Request a Quote
Have questions? Call 800.768.4200

General Description

  • The Cat® ECS 400 is designed for large industrial/ commercial installations. The Cat ECS 400 integrates a variety of traditional and renewable energy sources within a microgrid by providing optimized monitoring and control for up to 32 Distributed Energy Resource (DER) assets.

Panel

  • Rugged metal enclosure
  • NEMA 1 wall mountable
  • 396 mm (15.6”) industrial color touch-screen display
  • Cat PLC-based electronic control module
  • Ethernet router included
  • Input/Output Ethernet module for interfacing with ATS and other relays
  • Input Circuit Breaker Protection (Single phase 120/240 VAC 50/60 Hz)
  • Best Battery Diode (BBD) for backup
  • Cat PLE702 telematics device
  • Router for Internet connection to telematics with Ethernet connection
  • Operating temperature -20°C to 40°C (0 to 95% relative humidity)
  • Voltage & lightning protection

User Interface

  • Provides graphical human machine interface (HMI) to all control elements to simplify operator interactions with DER assets. Includes system visualization and user interface for manual or automatic control of the DERs.

Distributed Energy Resources (DER) Dispatch

  • Energy contribution from each of the DERs to maximize penetration from renewable energy sources and system reliability. Priority for distributed resource use can be changed from the Cat ECS 400 user interface.
  • Optimizing asset performance according to pre-programmed routines that can be adjusted via user-selectable criteria. The optimization routines can be based on several different parameters, such as minimizing fuel cost, optimizing engine operation, user configurable schedules for charging and discharging and grid export/import, charging batteries from PV only or maximizing system reliability.

Grid Import/Export Control

  • The Cat ECS 400 will regulate the amount of real and reactive power exported from DER's  to  the  utility based on a programmable set point.

Cat Engineering Services Custom Solutions

  • The Cat ECS provides the option to have Cat Engineering Services customize solutions to meet large site requirements worldwide.  

Microgrid Power Infrastructure Control Up To 32 Assets

Ability to monitor and control the complete microgrid power infrastructure with high system reliability and resiliency​

Multiple Applications

Seamless site integration leveraging over 50 years of Caterpillar Electric Power Industry experience

Customized site solutions​

Scalable and flexible solutions, comprehensive engineering and Services ensure reliable uptime

Technical Summary
ApplicationThe Cat ECS 400 is used in a variety of microgrids where the Cat ECS 400 is configurable to meet applicable site-specific asset requirements.
Module TypeMonitoring / control and asset optimization may be configured with up to 32 Distributed Energy Resources (DER's).
Environmental Parameters
Enclosure RatingNEMA 1 wall mountable

Applicable Codes and Standards

  • UL 508A; Note codes may not be available in all model configurations. Please consult your local Cat dealer for availability.
  • NEMA Type 1
  • SunSpec® Compliant

Standard Components

  • Best Battery Diode (BBD) for backup power supply.
  • Managed switch that offers configurable site communication and enhanced security provision to assure network integrity. One ethernet (4-Wire) port connection for customer networking of DER's.
  • Telematics PLE702 (See LEHE22212) allows data logging of 300 channels for 1.5 days (requires subscription for visualization).

Input/Output Ethernet Modules

  • Supports expanded Inputs/Outputs (IO) capability of the Cat ECS 400 control: - Analog & digital I/O - Temperature sensing (RTD).
  • Configure I/O for any event (read & write function).
  • Interface with a single ATS and other relays that allows load shed/load add with up to eight (8) load breakers.
  • Package mounted and/or ship loose options (See LEHE22466).

Control Modes | Auto | Grid Connected - Sub-modes (16):

  • Unplanned Islanding or Emergency standby - Closed transition (with soft unload) or Open transition
  • Planned Islanding or Intentional islanding
  • Load sense/load demand - Based on asset priority or engine-hour balancing - Automatically matches on-line asset capacity to the loads
  • Load shed/load add - Automatic or manual load shed up to eight (8) stages
  • Utility parallel, import power from grid - Minimum import kW setpoint is maintained
  • Utility parallel, export power to grid -Target export setpoint is maintained
  • Utility parallel, base load operations
  • Economy mode - All Gensets and non-renewable "fuel consuming" assets OFF
  • Reliability mode - At least one high priority "fuel consuming" asset ON
  • Scheduling - 5 schedules and 6 segments - BESS dispatch scheduling based on year, month, time, day and segment of day - 5 schedules and 6 segments - Import and export scheduling for active and reactive power based on time, day and segment of day
  • Load smoothing mode - Non-stable load dispatch using available assets for specified durations of time
  • 3 Flexible efficiency modes 1, 2 and 3 that may be set up based on asset group priorities
  • Pro-active add and drop - Ability to manually bring additional gensets online in anticipation of bringing on large loads. - Manually turning off gensets instead of waiting for LSLD drop when the customer knows large loads are being taken offline
  • Grid Reactive Control mode - There are 4 available reactive power control settings - Constant VAr, Constant PF, Volt-VAr curve, Watt-VAr curve.

Control Modes | Auto | Off-Grid (Island) - Sub-modes (7):

  • Pro-active add and drop - Ability to manually bring additional gensets online in anticipation of bringing on large loads - Manually turning off gensets instead of waiting for LSLD drop when the customer knows large loads are being taken offline

Control Modes | Manual |

  • Communications, power allocation test mode for site commissioning. Manually control assets and the microgrid system.

Control Modes | Idle |

  • Monitoring only - Cat ECS 400 relinquish control to another site controller.

Control Modes | Off |

  • Off

Cat Remote Breaker Control

  • Utility Protection Functions - American National Standards Institute (ANSI) - Over / Under Voltage (59 / 27) - Over / Under Frequency (81O / U) - Rate of Change of Frequency (ROCOF) (81R) - Sync check (25).
  • Cat® Energy Control System (ECS) 400
    application/pdf
  • Electric Power Ratings Guide
    application/pdf

Need installed dimensions with enclosure and tank? See Model Configurations