Standard Equipment Documents
Control Auto/Start/Stop Emergency stop Engine cooldown timer Engine cycle crank Programmable cycle timer Speed and voltage adjust Synchronizing Generator Monitoring Generator AC voltage monitoring (+/- 0.25% accuracy) Utility AC voltage monitoring (+/- 0.25% accuracy) 3 phase/4 wire (L-L & L-N) sensing Generator current sensing (3 phase/6 wire) (+/- 0.25% accuracy) Generator AC current (per phase and average) Generator frequency kWh, kVArh and import and export kVAh (total and trip) Generator stator and bearing temperature (with optional RTD module) kW load histogram Island paralleling up to 32 gensets Genset circuit breaker control Base load with utility Dead bus arbitration Failsafe adaptive load sharing/droop operation Generator Protection Generator phase sequence (47G) Bus phase sequence (47) Over/Under voltage (27/59) Over/Under frequency (81 O/U) Overcurrent timed and inverse (50/51) Overcurrent (thermal damage curve) (51) Reverse power real (kW) (32) Reverse power reactive (kVAr) (32RV) Current balance (46) Overload (49) Voltage imbalance (60) Arch flash maintenance mode Open phase detection Utility Protection Open Phase Detection Over/Under voltage and frequency (27/59) and (81O/U) Bus Protection Over/Under voltage and frequency (27/59) and (81O/U) Engine Monitoring Engine oil pressure (psi or kPa) Engine oil temperature (°C or °F) Engine coolant temperature (°C or °F) Engine speed (RPM) Battery voltage Crank attempt and successful start counter Run hour meter Real time clock Engine Protection Control switch not in auto (alarm) Low oil pressure High coolant temperature (alarm and shutdown) Low coolant temp (alarm) Low coolant level (alarm and shutdown) High engine oil temp (alarm and shutdown) Low/High/Weak battery voltage Fail to start Overspeed Overcrank Low gas pressure (alarm and shutdown) Communications Primary and accessory CAN data link Remote annunciator data link Cat Data Link - with optional PLE702 Ethernet (Modbus TCP/IP) - 100 baseT 8x 4-wire ports/managed switch (for internal and customer use) 4x 2-wire ports: internal device network Inputs & Outputs Digital Inputs: Emergency stop Digital Inputs: Remote start Digital Inputs: 32 programmable inputs (generator set configuration may affect available features) Digital Outputs: 24 programmable outputs (total) Digital Outputs: Up to 4 programmable outputs for functional safety Analog Outputs: 4 analog outputs PWM Outputs: 6 total (1 for IVR - standard) Analog Inputs: 6 programmable inputs 0-5V or resistive (generator set configuration may affect available features) Environmental Control Module Box Operating Temp: -40°C to +70°C (Storage Temp: -55°C to +85°C) Ingress Protection: IP66 (HMI Touchscreen from the front) Cat ECS 200 Control Panel
application/pdf
Download ↓ Need installed dimensions with enclosure and tank? See Model Configurations