C27 (60 Hz)
C27 (60 Hz)
C27 (60 Hz)
C27
C27 Enclosure
Diesel generator sets

C27 (60 Hz)

The C27 diesel generator sets have been developed for your mission critical, standby and prime applications. Producing reliable power from 635 to 800 ekW at 60 Hz, each generator set has been designed to meet ISO 8528-5 transient response requirements and to take on 100 % block load. The C27 is certified as a low fuel consumption system as well as having a certificate for EPA Stationary Emergency (Tier 2).

Request a Quote
Have questions? Call 800.768.4200

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load and meets NFPA 110 loading requirements with G3 Class load acceptance capability
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

SR5 Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

GCCP and CAT ECS

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

  • UL 2200
  • CSA
  • IBC seismic certification
  • OSHPD pre-approval

One Safe Source

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Field population 250,000 in service

Proven performance in heavy-duty applications

Integrated Cat Control system

Designed to match engine and alternator performance

G3 Class load acceptance capability and Accepts 100% block load

Can handle large loads without affecting operations

Generator Set Specifications
Standby Rating750/800 ekW
Prime Power Rating680/725 ekW
Emissions/Fuel StrategyLow BSFC / U.S. EPA Tier 2 Certified
Voltage208 to 600 Volts
Frequency60 Hz
Speed1800 rpm
Duty CycleStandby, Prime
Engine Specifications
Engine ModelC27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel
Bore5.4 in
Stroke6 in
Displacement1649.47 in³
Compression Ratio16.1:1
AspirationTA
Fuel SystemMEUI
Governor TypeAdem™A4
Generator Set Dimensions
Length - Maximum184 in
Width - Maximum67.8 in
Height - Maximum85.1 in

Air Inlet

  • Air cleaner; single element canister type with service indicator

Control Panel

  • GCCP 1.2
  • Digital Indicators
  • Warning/shutdown Indicators
  • Programmable protective relaying functions
  • Communications
  • Features include:

Cooling System

  • Coolant level sensor
  • Coolant drain line with valve terminated on edge of base
  • ATAAC
  • Caterpillar extended life coolant
  • Radiator sized to 50 degrees C
  • Fan and belt guards drive

Exhaust System

  • 203 mm (8 in) ID round flanged outlet
  • Exhaust manifold - dry

Fuel System

  • Primary fuel filter with integral water separator
  • Electric fuel priming pump
  • Fuel cooler
  • Flexible fuel lines - installed
  • Secondary fuel filters

Generators and Attachments

  • Integrated voltage regulator (IVR) includes
  • For EPA Stationary Emergency (EPA Tier 2 Emissions) configurations:
  • Busbar connections:
  • SR5 Permanent magnet excitation (PMG) (PM)
  • For Low BSFC configurations:

Lube System

  • Standard volume oil pan - 68 Ltr
  • Lubricating oil
  • Oil drain lines and valve
  • Gear type lube oil pump
  • Oil filter, filler and dipstick
  • Fumes disposal - open crankcase ventilation routed to front of package
  • Integral lube Oil cooler

Mounting System

  • Rubber anti-vibration mounts - shipped loose
  • Rails - engine/generator/radiator mounting

Starting and Charging System

  • 24-Volt electric starting motor
  • Battery, rack and cables - shipped-loose
  • Battery disconnect switch
  • Charging alternator 45A

General

  • Paint - Caterpillar yellow with high gloss black rails & radiator
  • SAE standard rotation
  • Right hand servicing
  • Flywheel and flywheel housing-SAE No. 0 and SAE No. 18
  • Electric Power Ratings Guide
    application/pdf
  • C27, 60 Hz, 750 ekW Standby 680 ekW Prime, Low Fuel Consumption Spec Sheet
    application/pdf
  • C27, 60 Hz, 750 ekW Standby 680 ekW Prime, U.S. EPA Emergency Stationary (Tier 2) Spec Sheet
    application/pdf

Need installed dimensions with enclosure and tank? See Model Configurations