C15 Rear Right
C15 Rear Left
C15 Front Right
C15 Front Left
Enclosure
Enclosure
Diesel generator sets

C15 (50 Hz) China Non Road

The C15 diesel generator sets have been developed for your mission critical, standby and prime applications. Producing reliable power from 365 to 550 kVA at 50 Hz, meeting ISO 8528-5 transient response requirements and built to accept 100 % rated load in one step. The engines are certified Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 or Tier 3 Nonroad Equivalent Emission Standards), EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards Emissions / Fuel Strategy.

Request a Quote
Have questions? Call 800.768.4200

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

A-Frame Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

GCCP1.3 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

One Safe Source

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Integrated Cat® Product Link™ Control System

Track Genset Health and Operation ParametersGenset Utilization and Performance Tracking

Remote Connectivity 24/7/365 Monitoring

Cat Connect option ensures your generator set is always ready to start and perform as expected

Optimised for 5% Lower Fuel Consumption

Longer run times between fuel fills; reduced operating costs

Generator Set Specifications
Standby Rating400/440 kVA
Prime Power Rating400/350 kVA
Emissions/Fuel StrategyChina Non-Road Stage III Certified
Voltage208 to 600 Volts
Frequency50 Hz
Speed1500 rpm
Duty CycleStandby, Prime
Engine Specifications
Engine ModelC15 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore5.4 in
Stroke6.75 in
Displacement927.56 in³
Compression Ratio16.1:1
AspirationAir to Air Aftercooled
Fuel SystemMEUI
Governor TypeAdem™A4
Generator Set Dimensions
Length - Maximum222.7 in
Width - Maximum90 in
Height - Maximum93.2 in

Air System

  • Aftercooler core
  • Turbocharger
  • Air cleaner - Non canister disposable paper filter

Air Inlet

  • Air cleaner

Control Panel

  • GCCP 1.3
  • GCCP 1.3

Cooling

  • Package mounted radiator

Cooling System

  • Radiator and cooling fan with guard
  • Coolant drain line with valve
  • Caterpillar extended life coolant
  • Fan drive, battery charging alternator drive

Fuel

  • Secondary fuel filters
  • Fuel priming pump
  • Primary fuel filter with integral water separator

Exhaust

  • Stainless steel exhaust flex, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
  • Exhaust flange outlet

Fuel System

  • Standard open set fuel tank/base supplied
  • Base, formed steel with single wall integral 8-hour fuel tank

Generator

  • IP23 Protection
  • Matched to the performance and output characteristics of Cat engines
  • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time

Generator and Attachments

  • IP23 Protection
  • A Frame generator - IP21 Protection
  • Segregated low voltage (AC/DC) wiring panel
  • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
  • Optional LC Frame generator - IP23 Protection
  • Power center, IP22
  • Integrated voltage regulator (IVR)

Power Termination

  • Busbar

Governing System

  • Cat electronic governor (ADEM A4)

Lube System

  • Lubricating oil
  • Oil drain valves

Mounting

  • Rubber vibration isolators

Mounting System

  • Rubber vibration isolators

Starting/Charging

  • 24 Volt battery with rack and cables
  • Batteries
  • 24 volt starting motor

General

  • Engine and alternator pre paint, Caterpillar yellow
  • Paint - Caterpillar yellow except rails and radiators gloss black
  • Electric Power Ratings Guide
    application/pdf
  • DE450C3, 50 Hz 450 kVA, China Non-Road III Emissions Compliant Spec Sheet
    application/pdf
  • DE500C3, 50 Hz 450 kVA, China Non-Road III Emissions Compliant Spec Sheet
    application/pdf

Need installed dimensions with enclosure and tank? See Model Configurations