3516E 50Hz Tier 2 / Low NOx
3516E 50Hz Tier 2 / Low NOx
3516E 50Hz Tier 2 / Low NOx
3516E 50Hz Tier 2 / Low NOx
3516E 50Hz Features
3516E, 50 Hz, 3000 kVA, Rear Right
3516E, 50 Hz, 3000 kVA, Rear Left
3516E, 50 Hz, 3000 kVA, Front Right
Diesel generator sets

3516E (50 Hz)

The 3516E diesel generator sets have been developed to meet your standby, mission critical and prime applications and match your power standards. Producing reliable power (2725 - 3500 kVA at 50 Hz), each generator set has been designed to meet ISO 8528-5 transient response requirements and to accept 100 % rated load in one step. The generator is certified Tier 2 Equivalent, US EPA Stationary Emergency / Low NOx (1/2 TA Luft).

Request a Quote
Have questions? Call 800.768.4200

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

SR5 Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

Cat ECS Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

  • EU Declaration of Conformity
  • EU Declaration of Incorporation
  • Eurasian Conformity (EAC)

One Safe Source

  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Saves up to 16% installed space

Requires less space for installation

Weighs up to 30% less

Reduced amount of structural support required

Full Power up to 50°C Ambient

Provides full power even on hottest days of the year

Generator Set Specifications
Standby Rating3500/3250/3000 kVA
Prime Power Rating3175/2950/2725 kVA
Emissions/Fuel StrategyU.S. EPA Cert. Tier 2 / Low NOx
Voltage380 to 11000 volts
Frequency50 Hz
Speed1500 rpm
Duty CycleStandby, Mission Critical, Prime
Maximum Rating3500 kVA
Minimum Rating2725 kVA
Engine Specifications
Engine Model3516E, V-16, 4-Stroke Water-Cooled Diesel
Bore6.69 in
Stroke8.46 in
Displacement4765 in³
Compression Ratio14.0:1
AspirationATAAC
Fuel SystemElectronic Unit Injection
Governor TypeAdem™ A5
Generator Set Dimensions
Length - Minimum313.4 in
Length - Maximum318.4 in
Width - Minimum104 in
Width - Maximum104 in
Height - Minimum131.6 in
Height - Maximum131.6 in
Dry Weight - Genset (minimum)44930 lb
Dry Weight - Genset (maximum)45651 lb

Air Inlet System

  • Air cleaner; single element canister type

Control System

  • Generator set packages include:
  • Emergency stop pushbutton
  • 24 Volt DC operation
  • KVAR / PF modes
  • IVR includes reactive droop capability
  • Cat ECS 100
  • Text alarm/event descriptions
  • Generator mounted - rear facing
  • Environmental sealed front face
  • RFI suppression
  • 3 Phase voltage sensing
  • Caterpillar's voltage regulator
  • Min / max exciter
  • Limiter and exciter diode monitor
  • Controls:
  • Speed adjust
  • Auto/start/stop control
  • Engine cycle crank
  • Engine cool
  • Alarm acknowledge
  • PLC functionality
  • Customizable screens
  • Lamp test
  • Load histogram feature
  • Generator phase sequence
  • 1 Programmable relay outputs (Form C)
  • RPM
  • High coolant temperature
  • Accessory module data link
  • Low coolant level
  • Number of I/O varies on options selected
  • Digital indication for:
  • Reverse power (kW) (32)
  • Reverse reactive power (kVAr) (32RV)
  • Overcurrent (50/51)
  • 6 Customer programmable digital inputs
  • 3 Analog inputs
  • Serial annunciator module data link
  • Over/under frequency (81 o/u)
  • Low coolant temperature
  • +/- 2% accuracy
  • Programmable protective relaying functions:
  • Failure to start (overcrank)
  • 4 Programmable relay outputs (Form A)
  • Cat connect
  • Over/under voltage (27/59)
  • 1 Programmable digital outputs
  • 0 True RMS AC metering
  • 3 Phase
  • Communications:
  • Overspeed
  • DC volts
  • Operating hours
  • Coolant temperature
  • Oil pressure (psi, kPa or bar)
  • Volts (L-L & L-N)
  • Power factor (per phase & average)
  • Frequency (Hz)
  • Amps (per phase & average)
  • kW (per phase, average & percent)
  • kVA (per phase, average & percent)
  • kVAr (per phase, average & percent)
  • Low oil pressure
  • kVAr-hr (total)
  • kW-hr (total)
  • Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -

Cooling System

  • ATAAC - 3516E package radiators shipped installed
  • Certified standard PGS provided

Exhaust System

  • Dry exhaust manifold
  • Flanged faced outlet(s)

Fuel System

  • Fuel cooler; not included with packages without radiator
  • Secondary fuel filters
  • Flexible fuel lines - shipped loose

General

  • SAE standard rotation
  • Flywheel and flywheel housing - SAE No. 00
  • Right hand servicing
  • Caterpillar yellow with high gloss black rails and radiator

Generator and Attachments

  • Anti-condensation space heater
  • Low voltage: Random wound - Internal excitation (IE) - Winding temperature detectors - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pattern
  • 3 Phase brushless, Salient pole
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
  • Winding temperature detectors
  • High voltage:
  • Medium voltage:
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
  • NEMA standard hole pattern
  • 6 Lead
  • Permanent magnet excitation (PMG)
  • Form wound
  • Busbar connections, right side extension box, bottom cable entry

Governing System

  • ADEM A5

Literature

  • Parts book
  • Operation & Maintenance Manual

Lubrication System

  • Gear type lube oil pump
  • Lubricating oil
  • Oil filter, filler and dipstick
  • Integral lube oil cool
  • Oil drain lines and valve
  • Fumes disposal

Mounting System

  • Rails - Engine/generator/radiator mounting
  • Anti-vibration mounts (shipped loose)
  • Rubber anti-vibration mounts - shipped loose

Starting System

  • 24 Volt electric starting motor
  • 45 Amp Charging alternator
  • Battery and battery rack w/cables
  • Battery disconnect switch
  • Electric Power Ratings Guide
    application/pdf
  • 3516E, 50 Hz, 2950 - 3500 kVA, Tier 2 Spec Sheet
    application/pdf
  • 3516E, 50Hz 2950 - 3500 kVA Low NOx Spec Sheet
    application/pdf
  • 3516E, 50Hz 2725 - 3000 kVA, Tier 2 (EPA ESE) with Low NOx Spec Sheet
    application/pdf
  • 3516E, 50 Hz, 2950/3175 kVA, Prime-DCP, Tier 2 Equivalent US. EPA Stationary Emergency Spec Sheet
    application/pdf
  • 3516E, 50 Hz, 2950/3175 kVA, Prime-DCP, Low NOx Spec Sheet
    application/pdf
  • 3516E, 50 Hz, 2725 kVA, Prime-DCP, Tier 2 (EPA ESE) with Low NOx Spec Sheet
    application/pdf

Need installed dimensions with enclosure and tank? See Model Configurations