3516B with Flexible Packaging
3516B with Flexible Packaging
3516 with Flexible Packaging
3516B with Flexible Packaging
Diesel generator sets

3516B (60 Hz) with Upgradeable Package

Producing reliable power from 1640 to 2250 ekW at 60 Hz, our 3516B diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. Generator sets offer both low fuel consumption and low emission systems.

Request a Quote
Have questions? Call 800.768.4200

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

SR5 Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

EMCP 4 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirements
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Single-Source Supplier

  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Over 4,000,000,000 Global Operating Hours

Proven performance in heavy-duty applications

Over 200,000 Shipped

Since 1981, leading the large engine market

Optimised for 8% Lower Fuel Consumption

Demonstrated savings in operating costs

Generator Set Specifications
Standby Rating2250 ekW
Prime Power Rating1825 ekW
Emissions/Fuel StrategyLow fuel, Low Emissions
Voltage380 to 480 Volts
Frequency60 Hz
Speed1800 rpm
Duty CycleStandby, Mission Critical, Prime, Continuous
Maximum Rating2250 ekW
Minimum Rating1640 ekW
Engine Specifications
Engine Model3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Bore6.69 in
Stroke7.48 in
Displacement4210.64 in
Compression Ratio14.0:1
AspirationTA
Fuel SystemMEUI
Governor TypeADEM™ A4
Generator Set Dimensions
Length - Maximum234.5 in
Width - Maximum90 in
Height - Maximum98.2 in
Dry Weight - Genset (maximum)30310 lb

Air Inlet System

  • Air cleaner; single element canister type

Control Panels

  • PLC functionality
  • Oil pressure (psi, kPa or bar)
  • Text alarm/event descriptions
  • KVAR/PF modes
  • Cat connect
  • Overspeed
  • Amps (per phase & average)
  • Programmable protective relaying functions:
  • DC volts
  • EMCP 4.2B
  • Power factor (per phase & average)
  • Reverse reactive power (kVAr) (32RV) - Overcurrent (50/51)
  • Load histogram feature
  • Generator set packages include:
  • Frequency (Hz)
  • Emergency stop pushbutton
  • Over/under voltage (27/59)
  • RFI suppression
  • 24 Volt DC operation
  • Low coolant level
  • Reverse power (kW) (32) - Reverse reactive power (kVAr) (32RV) - Overcurrent (50/51)
  • 4 Programmable relay outputs (Form A)
  • Volts (L-L & L-N)
  • Caterpillar's voltage regulator
  • IVR includes:
  • Auto/start/stop control
  • kVA (per phase, average & percent)
  • Lamp test
  • Over/under frequency (81 o/u)
  • Environmental sealed front face
  • 3 Phase voltage sensing
  • Engine cool
  • kVAr-hr (total)
  • Low oil pressure
  • Accessory module data link
  • Emergency stop
  • Customer data link (Modbus RTU)
  • Communications:
  • Warning/shutdown with common LED indication of shutdowns for:
  • 0 True RMS AC metering, 3-phase, +/-2% accuracy
  • Digital indication for:
  • Customizable screens
  • Failure to start (overcrank)
  • Serial annunciator module data link
  • Coolant temperature
  • Controls:
  • Overcurrent (50/51)
  • Number of I/O varies on options selected
  • Reactive droop capability
  • Low coolant temperature
  • High coolant temperature
  • Min / max exciter
  • Alarm acknowledge
  • RPM
  • Generator phase sequence
  • Limiter and exciter diode monitor
  • Speed adjust
  • Operating hours
  • kW (per phase, average & percent)
  • 3 Analog inputs
  • Generator mounted - rear facing
  • 6 Customer programmable digital inputs

Lubrication System

  • Oil filter, filler and dipstick
  • Oil drain lines and valve
  • Gear type lube oil pump
  • Fumes disposal
  • Lubricating oil

Mounting System

  • Rubber anti-vibration mounts - shipped loose
  • Rails - engine/generator/radiator mounting
  • Anti-vibration mounts (shipped loose)

Starting System

  • 45 Amp Charging alternator
  • 24 Volt electric starting motor
  • Battery and battery rack w/cables
  • Battery disconnect switch

Literature

  • Parts book
  • Operation & Maintenance Manual
  • Electric Power Ratings Guide
    application/pdf
  • 3516B Upgradeable, 60 Hz, 2000 ekW Standby/MC, 1825 ekW Prime, 1640 ekW Cont., Low Fuel Consumption and Low Emissions Spec Sheet
    application/pdf
  • 3516B Upgradeable, 60 Hz, 1825 ekW, Prime-DCP, Low Fuel Consumption or Low Emissions Spec Sheet
    application/pdf

Need installed dimensions with enclosure and tank? See Model Configurations