3512 (60 Hz) Upgradeable Package
3512 (60 Hz) Upgradeable Package
3512 (50 Hz) Upgradeable Package
3512 (60 Hz) Upgradeable Package
Diesel generator sets

3512 (60 Hz) with Upgradeable Package

Producing reliable power from 890 to 1250 eKW 60 Hz, our 3512 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. Generator sets are optimized for low fuel consumption.

Request a Quote
Have questions? Call 800.768.4200

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

SR5 Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

EMCP 4 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

One Safe Source

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Over 4,000,000,000 Global Operating hours

Proven performance in heavy-duty applications

Over 200,000 Shipped

Since 1981, leading the large engine market

Optimised for 6% Lower Fuel Consumption

Demonstrated savings in operating costs

Generator Set Specifications
Standby Rating1250/1100 ekW
Prime Power Rating1135/1000 ekW
Emissions/Fuel StrategyLow Fuel Consumption
Voltage380 to 480 Volts
Frequency60 Hz
Speed1800 rpm
Duty CycleStandby, Mission Critical, Prime, Continuous
Maximum Rating1250 ekW
Minimum Rating890 ekW
Engine Specifications
Engine Model3512A, V-12, 4-Stroke Water-Cooled Diesel
Bore6.69 in
Stroke7.48 in
Displacement3161.03 in³
Compression Ratio13.5:1
AspirationTA
Fuel SystemMUI
Governor TypeWoodward
Generator Set Dimensions
Length - Maximum203.5 in
Width - Maximum79.3 in
Height - Maximum92 in
Dry Weight - Genset (minimum)22099 lb
Dry Weight - Genset (maximum)22540 lb

Air Inlet System

  • Air cleaner; single element canister type with service indicator

Control Panel

  • Auto/start/stop control
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • kVAr-hr (total)
  • EMCP 4.2B
  • kVAr (per phase, average & percent)
  • Customer data link (Modbus RTU)
  • KVAR/PF modes, RFI suppression, min/max exciter
  • Overcurrent (50/51)
  • IVR includes reactive droop capability, 3-phase voltage sensing
  • Generator phase sequence
  • 6 programmable digital inputs
  • Engine cool-down timer
  • Limiter and exciter diode monitor
  • Over/under voltage (27/59)
  • Low coolant temperature
  • Generator set packages include Caterpillar's voltage regulator (IVR)
  • Accessory module data link
  • Low oil pressure
  • Over/under frequency (81 o/u)
  • Generator mounted - rear facing
  • Reverse reactive power (kVAr) (32RV)
  • Emergency stop
  • Lamp test
  • Overspeed
  • kVA (per phase, average & percent)
  • Operating hours
  • DC volts
  • Low coolant level
  • Programmable protective relaying functions:
  • Frequency (Hz)
  • Amps (per phase & average)
  • Environmental sealed front face
  • Failure to start (overcrank)
  • Power factor (per phase & average)
  • Controls:
  • kW (per phase, average & percent)
  • Oil pressure (psi, kPa or bar)
  • 24 Volt DC operation
  • 4 programmable relay outputs (Form A)
  • Emergency stop pushbutton
  • 2 Programmable relay outputs (Form C)
  • RPM
  • Digital indication for:
  • Engine cycle crank
  • Speed adjust
  • Coolant temperature
  • 2 Programmable digital outputs
  • Text alarm/event descriptions
  • Serial annunciator module data link
  • Communications:
  • kW-hr (total)
  • Volts (L-L & L-N)
  • Alarm acknowledge
  • Warning/shutdown with common LED indication of shutdowns for:
  • Reverse power (kW) (32)
  • High coolant temperature

Cooling System

  • Coolant level sensors (Not included with packages without radiator)
  • Coolant drain line with valve
  • Fan and belt guards
  • JWAC
  • Caterpillar extended life coolant. (Not included with packages without radiator, installed SF44CTS, shipped loose radiators or heat exchangers)
  • Caterpillar extended life coolant. (Not included with packages without radiator, installed SF44CTS, shipped loose radiators or heat exchangers)

Exhaust

  • Dry exhaust manifold
  • Flanged faced outlet(s)

Fuel System

  • Fuel priming pump
  • Fuel cooler; not included with packages without radiator
  • Secondary fuel filters
  • Flexible fuel lines - shipped loose

Generators and Attachments

  • Internal excitation (IE) or Permanent magnet excitation (PMG)
  • Winding temperature detectors
  • 6 Lead
  • LV
  • 60 Hz models: NEMA standard hole pattern
  • Busbar connections, top center mounted, top cable entry
  • 3 Phase brushless, Salient pole
  • Random wound
  • NEMA Class H insulation
  • Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • KVAR/PF modes
  • Exciter diode monitor
  • Caterpillar's digital voltage regulator (CDVR) includes:
  • RFI suppression
  • Reactive droop capability
  • Min / max exciter limiter
  • Note: 1800 Frames are form wound, permanent magnet excitation (PMG), with winding temp detectors
  • Generator set packages include: Regulator (CDVR)
  • 3 Phase voltage sensing

Governing System

  • Woodward 2301A isochronous governor

Lube System

  • Fumes disposal
  • Lubricating oil
  • Gear type lube oil pump
  • Oil filter, filler and dipstick
  • Integral lube Oil cooler
  • Oil drain lines and valve

Mounting System

  • Rails - engine/generator/radiator mounting
  • Rubber anti-vibration mounts - shipped loose

Starting / Charging System

  • 24-Volt electric starting motor
  • Battery and battery rack w/cables
  • 50 Amp Charging alternator
  • Battery disconnect switch

General

  • Flywheel and Flywheel housing-SAE No. 00
  • SAE standard rotation
  • RH service
  • Paint - Caterpillar yellow with high gloss black rails & radiator
  • Electric Power Ratings Guide
    application/pdf
  • 3512, 60 Hz, 1250 ekW Standby/MC, 1135 ekW Prime, 1010 ekW Cont., Low Fuel Consumption Spec Sheet
    application/pdf
  • 3512, 60 Hz, 1135 kVA, Prime-DCP, Low Fuel Consumption Spec Sheet
    application/pdf

Need installed dimensions with enclosure and tank? See Model Configurations