3512 MUI Modular Rear Overhang Generator Set (Rear Right)
3512 MUI Modular Rear Overhang Generator Set (Rear Left)
3512 MUI Modular Rear Overhang Generator Set (Front Left)
3512 MUI Modular Rear Overhang Generator Set (Front Right)
Diesel generator sets

3512 (50 Hz)

Producing reliable power from 1150 to 1400 kVA at 50 Hz, our 3512 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. Generator sets offer a low fuel consumption system.

Request a Quote
Have questions? Call 800.768.4200

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

SR5 Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

EMCP 4 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

  • Telecom Lab of China (TLC)
  • EU Declaration of Conformity
  • EU Declaration of Incorporation
  • Eurasian Conformity

One Safe Source

  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Over 4,000,000,000 Global Operating Hours

Proven performance in heavy-duty applications

Over 200,000 Shipped

Since 1981, leading the large engine market

Full Power up to 50°C Ambient

Provides full power even on hottest days of the year

Generator Set Specifications
Standby Rating1400/1250 kVA
Prime Power Rating1275/1150 kVA
Emissions/Fuel StrategyLow Fuel Consumption
Voltage380 to 415 Volts
Frequency50 Hz
Speed1500 rpm
Duty CycleStandby, Mission Critical, Prime, Continuous
Maximum Rating1400 kVA
Minimum Rating1000 kVA
Engine Specifications
Engine Model3512 TA, V-12, 4-Stroke Water-Cooled Diesel
Bore6.69 in
Stroke7.48 in
Displacement3161.03 in³
Compression Ratio13.5:1
AspirationTA
Fuel SystemDirect Unit Injection
Governor TypeWoodward
Generator Set Dimensions
Length - Minimum218.8 in
Length - Maximum222.9 in
Width - Minimum77.8 in
Width - Maximum78.1 in
Height - Minimum90.7 in
Height - Maximum93.2 in
Dry Weight - Genset (minimum)22650 lb
Dry Weight - Genset (maximum)23678 lb

Air Inlet System

  • Air cleaner; single element canister type with service indicator

Control Panel

  • EMCP4.2B controls includes: Emergency stop pushbutton
  • RPM
  • Engine cool-down timer
  • EMCP4.2B controller includes:
  • Accessory module data link
  • 4 programmable relay outputs (Form A)
  • Communications:
  • Volts (L-L & L-N)
  • Over/under frequency (81 o / u)
  • Text alarm/event descriptions
  • Auto/start/stop control
  • Speed adjust
  • kVA (per phase, average & percent)
  • Overcurrent (50 / 51)
  • Alarm acknowledge
  • Environmental sealed front face
  • 6 programmable digital inputs
  • Oil pressure (psi, kPa or bar)
  • Amps (per phase & average)
  • Generator phase sequence
  • 2 Programmable digital outputs
  • Low coolant temperature
  • Controls:
  • Serial annunciator module data link
  • Reverse power (kW) (32)
  • Lamp test
  • Coolant temperature
  • Engine cycle crank
  • kVAr-hr (total)
  • 2 Programmable relay outputs (Form C)
  • Generator mounted - rear facing
  • 24 Volt DC operation
  • kVAr (per phase, average & percent)
  • Warning/shutdown with common LED indication of shutdowns for:
  • kW (per phase, average & percent)
  • Reverse reactive power (kVAr) (32RV)
  • Programmable protective relaying functions:
  • Digital indication for:
  • High coolant temperature
  • Low oil pressure
  • Overspeed
  • Over/under voltage (27 / 59)
  • Customer data link (Modbus RTU)
  • DC volts
  • Operating hours
  • Low coolant level
  • kW-hr (total)
  • Frequency (Hz)
  • Emergency stop
  • Power factor (per phase & average)
  • Failure to start (overcrank)
  • True RMS AC metering, 3-phase, +/-2% accuracy

Cooling System

  • JWAC
  • Caterpillar extended life coolant. (Not included with packages without radiator, installed SF44CTS, shipped loose radiators or heat exchangers)
  • Radiator fan and fan drive
  • Fan and belt guards
  • Coolant drain line with valve
  • Coolant level sensors (Not included with packages without radiator)

Exhaust System

  • Dry exhaust manifold
  • Flanged faced outlet(s)

Fuel System

  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
  • Fuel priming pump
  • Secondary fuel filters

Generators and Attachments

  • Generator set packages include: Regulator (CDVR)
  • 6 Lead
  • Min / max exciter limiter
  • LV
  • Reactive droop capability
  • Random wound
  • Exciter diode monitor
  • KVAR/PF modes
  • NEMA Class H insulation
  • 50 Hz models: IEC standard hole pattern
  • Caterpillar's digital voltage regulator (CDVR) includes:
  • Note: 1800 Frames are form wound, permanent magnet excitation (PMG), with winding temp detectors
  • Busbar connections, top center mounted, top cable entry
  • Internal excitation (IE)
  • Winding temperature detectors
  • Class H temperature rise at 40C ambient (125C prime/150C standby)
  • 3 Phase brushless, Salient pole
  • 3 Phase voltage sensing
  • RFI suppression

Governing System

  • Woodward 2301A isochronous governor

Lube System

  • Oil drain lines and valve
  • Gear type lube oil pump
  • Fumes disposal
  • Oil filter, filler and dipstick
  • Lubricating oil
  • Integral lube Oil cooler

Mounting System

  • Rubber anti-vibration mounts - shipped loose
  • Rails - engine/generator/radiator mounting

Starting / Charging System

  • 24 Volt electric starting motor
  • Battery and battery rack w/cables
  • Battery disconnect switch

General

  • Paint - Caterpillar yellow with high gloss black rails & radiator
  • SAE standard rotation
  • RH service
  • Flywheel and Flywheel housing - SAE No. 00
  • Electric Power Ratings Guide
    application/pdf
  • 3512, 50 Hz, 1400 kVA Standby/MC, 1275 kVA Prime, 1206 kVA Cont., Low Fuel Consumption Spec Sheet
    application/pdf
  • 3512, 50 Hz, 1275 kVA, Prime-DCP, Low Fuel Consumption Spec Sheet
    application/pdf

Need installed dimensions with enclosure and tank? See Model Configurations