3412C Diesel Generator Sets
3412C Diesel Generator Set
3412C Diesel Generator Set
3412C Diesel Generator Set
Diesel generator sets

3412C (60 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Request a Quote
Have questions? Call 800.768.4200

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

SR500 Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

EMCP 4 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

One Safe Source

  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Accepts 100% block load in 1 step

Can handle large loads without affecting operations

Utilizes the latest ADEM 5 Controller

Provides precise control over entire range of loads

Upgradeable controls. Allows for easy retrofit of EMCP 4.3/4.4 Controllers

Generator Set Specifications
Standby Rating700/750/800 ekW
Prime Power Rating635/680/725 ekW
Emissions/Fuel StrategyLow BSFC
Voltage220 to 480 Volts
Frequency60 Hz
Speed1800 rpm
Duty CycleStandby, Prime
Engine Specifications
Engine Model3412C TA, V-12, 4-Stroke Water-Cooled Diesel
Bore5.4 in
Stroke6 in
Displacement1648.86 in³
Compression Ratio13:00:01
AspirationTA
Fuel SystemPump and Lines
Governor TypeADEM™ A5
Generator Set Dimensions
Length - Maximum162.4 in
Width - Maximum78.3 in
Height - Maximum75 in
Dry Weight - Genset (minimum)5761 lb
Dry Weight - Genset (maximum)13275 lb

Air Inlet System

  • Air cleaner, single element canister type
  • Single element canister type

Control Panel

  • High coolant temperature
  • Customer data link (Modbus RTU)
  • Low coolant temperature
  • Low coolant level
  • Communications:
  • Run/auto/ stop/control
  • Engine cycle crank
  • Generator temperature monitoring module
  • Power factor (per phase & average)
  • Remote CAN annunciator
  • Serial annunciator module data link
  • DC volts
  • Frequency (Hz)
  • Operating hours.
  • Emergency stop pushbutton
  • Digital I/O module
  • Local annunciator
  • Low oil pressure
  • Oil pressure (psi, kPa or bar)
  • Emergency stop
  • Warning shutdowns:
  • Volts (L-L & L-N)
  • Remote Serial annunciator
  • Speed adjust
  • Amps (per phase & average)
  • Voltage adjust
  • EMCP 4.2B
  • Overspeed
  • coolant temperature
  • Digital Indicator for:
  • RPM
  • Accessory module data link
  • Failure to start (overcrank)
  • Controls:
  • Compatible with the following optional modules:

Cooling System

  • Caterpillar extended life coolant
  • Radiator with guard (sized for 50 degrees C)
  • Fan and belt guards
  • Coolant drain line with valve

Exhaust System

  • Stainless steel exhaust flex with ANSI style outlet flange

Fuel System

  • Primary and Secondary fuel filters
  • Fuel priming pump
  • Water separator

Generator and Attachments

  • 3 Phase sensing
  • SR4B self excited
  • Class F temperature rise
  • VR6B voltage regulator
  • Busbar termination
  • 12 Leads
  • Class H insulation
  • 2:1 Volts/Hz
  • Reactive droop

Governing System

  • Cat electronic governor

Lube System

  • Oil drain line with valve
  • Lubricating oil
  • Oil filter

Mounting System

  • Base, formed steel with linear vibration isolators between base and engine-generator

Starting / Charging System

  • Battery with rack, cables
  • 45 Amp Charging alternator
  • Fuel shutoff solenoid
  • 24 Volt starting motor

General

  • Paint - Caterpillar yellow except rails and radiators gloss black
  • Electric Power Ratings Guide
    application/pdf
  • 3412, 60 Hz, 635-800 ekW, Low Fuel Consumption Spec Sheet
    application/pdf
  • 3412, 60 Hz, 635-800 ekW, Low Fuel Consumption Spec Sheet
    application/pdf

Need installed dimensions with enclosure and tank? See Model Configurations