The Cat 3516C is offered at 1506 bkW (2100 bhp) @ 1750 rpm. This engine is available using EPA (U.S.) Flex provisions and for other global regulated and non-regulated areas. The 3516C offers unsurpassed performance and durability in a multitiude of industries and applications, including Bore and Drill Rigs, Chippers, Grinders, and Shredders, Cranes, Dredgers, Forestry, Material Handling, Mining and Pumps.

Request a Quote
Have questions? Call 800.768.4200
Power Rating
Maximum Power2100 hp
Maximum Torque7563 lb-ft @ 1300 rpm
Rated Speed1750 rpm
Minimum Power2100 hp
Emission Standards
EmissionsU.S. EPA Tier 2 Nonroad Equivalent Emission Standards (Not Currently EPA Certified)
General
Engine ConfigurationV-16, 4-Stroke-Cycle Diesel
Bore6.7 in
Stroke8.5 in
Displacement4760 in³
Compression Ratio14.7:1
AspirationTurbocharged Aftercooled
Rotation from Flywheel EndCounterclockwise
Aftertreatment-
Engine Dimensions - Approximate
Length129.1 in
Width60.2 in
Height81.2 in
Weight - Net Dry - Basic Operating Engine Without Optional Attachments17284 lb

Air Inlet System

  • Air to Air Aftercooled (ATAAC)
  • Four turbochargers, center mounted

Control System

  • ADEM A4 ECM Electronic Engine Control, RH (10 amp DC power required)

Cooling System

  • Thermostats and housing
  • Gear driven centrifugal jacket water pump
  • Connections for radiator cooling

Exhaust System

  • Exhaust manifold, dry
  • Four turbochargers with watercooled bearings
  • Two exhaust outlets, 203 mm (8 in) round flange

Flywheels and Flywheel Housing

  • SAE No. 00 flywheel (183 teeth)
  • SAE No. 00 flywheel housing

Fuel System

  • Fuel filter, LH spin-on type
  • Fuel transfer pump
  • Electronically controlled unit injectors

Instrumentation

  • No standard instrument or gauge panel

Lube System

  • Crankcase breather, top mounted
  • Oil cooler
  • Oil filler and dipstick, LH
  • Oil pump
  • Oil filter, LH, spin-on type
  • Front sump oil pan, 500-hour change interval

Mounting System

  • Trunnion front support

Power Take Off

  • Front housing, two-sided

Protection System

  • ADEM A4 ECM monitoring system to provide customer programmable engine
  • Deration strategies to protect against adverse operating conditions
  • Emergency stop logic inputs provided at 40 pin customer interface connection

Starting System

  • Dual 24V electric starting motor, LH, unwired

General

  • Paint: Caterpillar yellow
  • Vibration damper
  • Lifting eyes

Need installed dimensions with enclosure and tank? See Model Configurations