Diesel generator sets

C4.4 (60 Hz)

Producing reliable power from 36 to 60 ekW at 60 Hz, our C4.4 diesel generator sets designed to ISO 8528-5 transient response requirements. All C4.4 generator sets meet EPA Stationary Emergency (Tier 3) emissions standards.

Request a Quote
Have questions? Call 800.768.4200
Generator Set Specifications
Maximum Rating60 ekW
Minimum Rating36 ekW
Emissions/Fuel StrategyU.S. EPA Cert., Tier 3
Voltage208 to 600 Volts
Frequency60 Hz
Speed1800 rpm
Duty CycleStandby, Prime
Engine Specifications
Engine ModelC4.4, In-line 4, 4-cycle diesel
Bore4.13 in
Stroke5 in
Displacement268.5 in
Compression Ratio18.2:1
AspirationTurbocharged
Fuel SystemElectronic (adjustable)
Governor TypeAdem™A4
Generator Set Dimensions
Length - Maximum75.8 in
Width - Maximum44.1 in
Height - Maximum53.6 in

Certificates

  • IBC seismic and wind Certifications

Charging System

  • NFPA battery charger UL10A 120VAC

Air Inlet System

  • Air cleaner
  • Cartridge type air filter

Circuit breakers

  • Second circuit breaker box
  • 3-Pole 100% rated
  • Power terminal strip
  • Breakers (100% UL rated)

Control Panel

  • 1000028996

Exhaust System

  • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose

Fuel System

  • Standard open set fuel tank/base supplied base, formed steel with single wall integral 8-hour fuel tank

Cooling System

  • Coolant drain line with valve
  • Radiator and cooling fan with guards
  • Fan drive, battery charging alternator drive
  • Caterpillar extended life coolant
  • Radiator stone guard

Generator

  • 12 Leads

Governing System

  • Mechanical and electrical governing system - model dependent

Lube System

  • Oil drain line with valve
  • Lubricating oil

Control Panels

  • WCA1 Low coolant temperature alarm
  • WSS1 Low coolant level shut down
  • FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
  • NFPA110 bundle includes:
  • PAA1 Panel mounted audible alarm
  • A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
  • Oil temperature gauge and sender
  • PBC10NU NFPA battery charger
  • Ground fault relay
  • Discrete I/O module
  • Volt free contacts genset run and common alarm
  • Audible alarm
  • Remote E-stop button
  • Remote annunciator module
  • Low coolant temperature alarm
  • Protective devices:
  • Overload shutdown via breaker
  • Fuel level reading
  • Low coolant level shutdown

General

  • Engine and alternator pre-paint, Caterpillar yellow

Starting/Charging System

  • 24V battery with rack and cables
  • Batteries
  • Electric Power Ratings Guide
    application/pdf
    Download ↓
  • 60 Hz 40 ekW, EPA Tier III Compliant Emissions Spec Sheet
    application/pdf
    Download ↓
  • 60 Hz 60 ekW, EPA Tier III Compliant Emissions Spec Sheet
    application/pdf
    Download ↓
  • 60 Hz 50 ekW, EPA Tier III Compliant Emissions Spec Sheet
    application/pdf
    Download ↓
  • 60 Hz 36 ekW, SCAQMD & US EPA Tier 3 equivalent Compliant Emissions Spec Sheet
    application/pdf
    Download ↓
  • 60 Hz 40 ekW, SCAQMD & US EPA Tier 3 equivalent Compliant Emissions Spec Sheet
    application/pdf
    Download ↓
  • 60 Hz 45 ekW, SCAQMD & US EPA Tier 3 equivalent Compliant Emissions Spec Sheet
    application/pdf
    Download ↓
  • 60 Hz 50 ekW, SCAQMD & US EPA Tier 3 equivalent Compliant Emissions Spec Sheet
    application/pdf
    Download ↓
  • 60 Hz 60 ekW, U.S. EPA Certified for Stationary Emergency Application Compliant Emissions Spec Sheet
    application/pdf
    Download ↓
  • 60 Hz 55 ekW, U.S. EPA Certified for Stationary Emergency Application Compliant Emissions Spec Sheet
    application/pdf
    Download ↓

Need installed dimensions with enclosure and tank? See Model Configurations